Starting Small... Building Big! With Alban CAT Construction Equipment...

Learn More
3516E High Voltage Generator Set Specifications
Minimum Rating 2750 kVA
Maximum Rating 3000 kVA (3100 kVA without fan)
Voltage 6300 to 11000 volts
Frequency 50 Hz

Generator Set Specifications

Minimum Rating
2750 kVA
Maximum Rating
3000 kVA (3100 kVA without fan)
Voltage
6300 to 11000 volts
Frequency
50 Hz
Speed
1500 RPM

Generator Set Configurations

Emissions/Fuel Strategy
Low Fuel Consumption

Engine Specifications

Engine Model
3516E, SCAC, V-16, 4-Stroke, Water-Cooled Diesel
Compression Ratio
14:1
Aspiration
TA
Aspiration
TA
Governor Type
Adem™5
Fuel System
Electronic unit injection
Fuel System
Electronic unit injection
Bore
6.69 in
Stroke (HD)
8.46 in
Bore
6.69 in
Stroke - HD
8.46 in
  • Air Inlet System
    • Air cleaner
    • Single element canister type with service indicator
  • Control Panel
    • EMCP4.2
    • Emergency stop pushbutton
    • Panel Lights
    • EMCP4.2 controller includes:
    • 24-volt DC operation
    • Environmental sealed front face
    • Text alarm/event descriptions
    • Generator mounted - rear facing
    • Generator set packages include Caterpillar' s Voltage Regulator (IVR). IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter. Limiter and exciter diode monitor
    • Controls:
    • Speed adjust
    • Engine cool-down timer
    • Engine cycle crank
    • Alarm acknowledge
    • Lamp test
    • Load histogram feature
    • PLC functionality
    • Customizable screens
    • True RMS AC metering, 3-phase, +/-2% accuracy
    • Digital indication for:
    • RPM
    • DC volts
    • Operating hours
    • Oil pressure (psi, kPa or bar)
    • Coolant temperature
    • Volts (L-L & L-N)
    • Frequency (Hz)
    • Amps (per phase & average)
    • Power Factor (per phase & average)
    • kW (per phase, average & percent)
    • kVA (per phase, average & percent)
    • kVAr (per phase, average & percent)
    • kW-hr (total)
    • kVAr-hr (total)
    • Warning/shutdown with common LED indication of shutdowns for:
    • Low oil pressure
    • High coolant temperature
    • Overspeed
    • Emergency stop
    • Failure to start (overcrank)
    • Low coolant temperature
    • Low coolant level
    • Programmable protective relaying functions:
    • Generator phase sequence
    • Over/Under voltage (27/59)
    • Over/Under Frequency (81 o/u)
    • Reverse Power (kW) (32)
    • Reverse Reactive Power (kVAr) (32RV)
    • Overcurrent (50/51)
    • Communications:
    • Customer data link (Modbus RTU)
    • Accessory module data link
    • Serial annunciator module data link
    • Cat Connect
    • 3 Analog inputs
    • 6 Customer programmable digital inputs
    • Number of I/O varies on options selected
    • 4 programmable relay outputs (Form A)
    • 1 programmable relay outputs (Form C)
    • 1 programmable digital outputs
  • Cooling System
    • Certified standard PGS provided
    • ATAAC
  • Exhaust System
    • Dry exhaust manifold
    • Flanged faced outlet(s)
  • Fuel System
    • Secondary fuel filters
    • Fuel cooler; not included with packages without radiator
    • Flexible fuel lines - shipped loose
    • Fuel priming pump
  • Generators and Attachments
    • 3 phase brushless, salient pole
    • 6 lead
    • Form Wound
    • Permanent magnet
    • Winding temperature detectors
    • Anti Condensation Space Heater
    • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
  • Governing System
    • Woodward A3
  • Literature
    • English
  • Lube System
    • Lubricating oil
    • Gear type lube oil pump
    • Integral lube oil cooler
    • Oil filter, filler and dipstick
    • Oil drain lines and valve
    • Fumes disposal
  • Mounting System
    • Rails - engine/generator/radiator mounting
    • Anti-vibration mounts (shipped loose)
    • Rubber anti-vibration mounts (shipped loose)
  • Starting / Charging System
    • 24-volt electric starting motor
    • 45 Amp charging alternator
    • Battery and battery rack w/cables
    • Battery disconnect switch
  • General
    • Paint: Caterpillar yellow with high gloss black rails & radiator
    • Right hand servicing
    • Flywheel and flywheel housing-SAE No. 00
    • SAE standard rotation
  • Air Inlet System
    • Single element filter
    • Dual element air cleaners
  • Control Panels
    • EMCP4.2B, EMCP4.3, EMCP4.4
    • Language options
    • Annunciator modules
    • Load share module options
    • Auxiliary box
    • PC monitoring (Remote and local)
    • Vandal proof panel door
    • Ground
  • Cooling System
    • Standard ambient radiators
    • Standard ambient ATAAC radiators
    • Optionally installed radiators
    • Optionally insstalled ATAAC radiators
    • Water level switch gauges
    • Coolant
  • Exhaust System
    • Elbows
    • Flange and exhaust expanders
    • Flanges
    • Flexible fittings
    • Y adapters
    • Mufflers
    • Exhaust offset
    • Clean emission parts - Harness from engine to DC - Basic and IBC stands
  • Fuel System
    • Primary fuel filters
  • Generators and attachments
    • 3 Phase, 1500 rpm, FW, PM, No. of Leads = 6, Pitch = .6667
    • Generator 2700 and 3000 frames
    • Thermostat for space heater
    • Current transformers
    • Alternator air cleaner
    • Differential current transformers (DCT) 8.7 and 15 kV class
  • Instrumentation
    • Pyrometer and termocouples
  • Lube System
    • Lube oil in standard sump
    • Oil level regulator
    • Prelube pump groups
    • Crankcase protection groups - No explosion relieve valves - Explosion relief valves
    • Crankcase ventilation system
  • Mounting System
    • Puck style low efficiency isolators
    • Spring type vibration isolators
    • IBC (International Building Code) seismic vibration Isolators
  • Power connections
    • 2700 & 3000 frame grounding groups
    • Neutral ground connections
    • Center post busbar
    • Left and right side cable entries
  • Special Tests / Reports
    • IBC certifications
    • PGS test report @ 1.0 power factor
    • PGS test report @ 0.8 power factor
    • Standard engine test charge
    • Fuel consumption test
    • Torsional vibration analysis
  • Starting / Charging System
    • Engine barring device
    • 24 Volt battery set - Dry
    • 10, 20, 35 and 50 amp battery chargers
    • Electric starting motors
    • Air starting motors
    • Starter covers
    • Air pressure regulator
    • Jacket water heaters
  • General
    • US aid emblem
    • Special paint colors
  • Extended Service Coverage
    • Silver, Gold and Platinum coverage from 24 to 120 month coverage (1,500 to 5000 hours