C175-16 Tier 4 Final Specifications
Minimum Rating 2500 ekW
Maximum Rating 3100 ekW
Voltage 480 - 13800 Volts
Frequency 60 Hz

Generator Set Specifications

Minimum Rating
2500 ekW
Maximum Rating
3100 ekW
Voltage
480 - 13800 Volts
Frequency
60 Hz
Speed
1800 RPM
Height - Maximum
134.3 in
Length - Maximum
312.9 in
Width - Maximum
113.7 in

Generator Set Configurations

Emissions/Fuel Strategy
U.S. EPA Certified for Non-Emergency Stationary Genset

Engine Specifications

Engine Model
C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel
Exhaust Flange Size (Internal Diameter)
150 mm (6.0 in)
Compression Ratio 50 Hz
16:7:1
Compression Ratio 50 Hz
16:07:01
Compression Ratio 60 Hz
15:3:1
Compression Ratio 60 Hz
15:03:01
Aspiration
Turbo Aftercooled
Aspiration
Turbo Aftercooled
Governor Type
ADEM™ A4
Fuel System
Common Rail
Fuel System
Common Rail
Bore
8.89 in
Displacement
5155.88 in³
Stroke
8.66 in
Bore
8.89 in
Displacement
5155.88 in³
Stroke
8.66 in
  • Air Inlet System
    • Air Cleaner; 4 x single element canister with service indicator(s).
  • Control Panel
    • EMCP4.3 controls including emergency stop button
    • EMCP4.3 controller including: 24-volt DC operation - Environmental sealed front face - Text alarm/event descriptions
    • Warning/shutdown with common LED indication of shutdowns with indicating lights for: Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant level (requires optional coolant sensor)
    • Generator mounted - rear facing
    • Controls: Speed adjust - Auto/start/stop control - Engine cool-down timer - Engine cycle crank - Alarm acknowledge - Lamp test
    • True RMS AC metering, 3-phase, +/-0.25% accuracy
    • Digital indication for: RPM - DC volts - Operating hours - Coolant temperature - Volts (L-L & L-N) - Frequency (Hz) - Amps (per phase & average) - Power Factor (per phase & average) - kW (per phase, average & percent) - kVA (per phase, average & percent) - kVAr (per phase, average & percent) - kW-hr (total) - kVAr-hr (total)
    • Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - High Coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level Over / Under voltage (27/59) - Over / Under frequency (81 o/u) - Reverse power (kW) (32) - Reverse reactive power (kVAr) (32RV) - Overcurrent (50/51)
    • Communications: Customer data link (Modbus RTU) - Accessory module data link - Serial annunciator module data link - 6 programmable digital inputs - 4 programmable relay outputs (Form A) - 2 programmable relay outputs (Form C) - 2 programmable digital outputs - 12 programmable digital inputs - 16 programmable digital outputs - 3 programmable analog inputs - 3 programmable analog outputs - 2 programmable PWM outputs
    • Local annunciator option
  • Cooling System
    • SCAC cooling
    • Radiator group shipped loose.
    • Fan and belt guards
    • Coolant drain line and valves
    • Coolant sensor - (2 x shipped loose: 1/4-18 and 1/2-14 NPTF).
  • Exhaust System
    • Insulated CEM
    • CEM dosing module
    • CEM dosing module features: Air filter - DEF filter - 120 VAC - Anti-freeze protection
    • Harness from dosing module to CEM
    • Air and heated DEF lines from dosing module to CEM
    • Dry exhaust manifold
    • Flanged faced outlets at CEM in (21.2") and out (25")
  • Fuel System
    • Primary fuel filter water / fuel water separator
    • 10 Micron spin on type
    • 3 Filters, shipped loose - can be mounted on frame rails (Requires dealer provided flex)
    • Secondary / tertiary fuel filters
    • 4 Micron Spin On Type
    • 3 Filters, engine mounted
  • Generator and Attachments
    • 3 Phase brushless, salient pole
    • 6 lead
    • IEC platinum stator RTDs (.00385 temperature coefficient)
    • Caterpillar's digital voltage regulator (CDVR) includes: Reactive droop capability - 3-Phase voltage sensing - KVAR / PF modes - RFI suppression - Min / Max exciter limiter - Exciter diode monitor
    • 1800 Frame generators (LV/MV)
    • Form wound
    • NEMA Class H insulation
    • Class H temperature rise at 40C ambient (125C prime / 150C standby)
    • (LV) Bus bar connections, top / center mounted, top cable entry 60 Hz models: NEMA standard hole pattern
    • (MV)Bus bar connections, right side extension box, bottom cable entry: - 60 Hz models: NEMA standard hole pattern
    • 3000 Frame generators (MV/HV)
    • Form wound
    • Permanent magnet
    • Anti condensation space heater
    • NEMA Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
    • Right side extension box, bottom cable entry
  • Governing System
    • ADEM A4
    • Redundant shutdown (Overspeed protection through a duplicate speed sensing system)
  • Lube System
    • Lubricating oil
    • Gear type lube oil pump
    • Integral lube oil cooler
    • Oil filter, filler and dipstick
    • Oil drain lines and valve
    • Fumes disposal
    • Prelube - required with prime and continuous; optional with standby
  • Mounting System
    • Rails - Engine / Generator
    • Rubber anti-vibration mounts (shipped loose).
    • Dual 24-volt electric starting motors
    • Batteries and battery rack w/cables
    • Battery disconnect switch
  • Service Instructions
    • Two PM Inspections
  • General
    • Paint - Caterpillar yellow with high gloss black rails & radiator
    • RH Service (except oil filter service 60 Hz models: left hand service
    • Flywheel and flywheel housing-SAE No. 00
    • SAE standard rotation
    • *For HV EMCP4.3 control panel: Includes wall mount control panel, shipped loose, for customer mounting and 7.5 meter interconnect harness.
    • * For HV applications, customer to provide 120V secondary sensing, 5A secondary current sensing and harness between package and EMCP4.3 (drawing provided). CDVR is installed in wall mount.
  • Air Inlet System
    • Single stage air cleaner
  • Control Panels
    • EMCP 4.3
    • EMCP 4.4 requires 1800 frame low voltage packages
    • E-Stop - Only for use with 3000 frame generators and EMCP4.3
    • Load share module
    • EMCP mounting location - LV / MV -- requires 1800 frame generator
    • Customer AC-DC connection mounting location - LV / MV
    • Load share governor / auxiliary plate and auxiliary box (LV)
    • Remote speed adjust
    • Annunciator modules
    • Customer interface options
    • Generator temperature monitoring
    • Modbus monitoring of packages
    • Vandal proof panel door
  • Cooling System
    • Package mounted radiator
    • Remote radiators
    • SCAC circuits
    • Fuel cooler
  • Exhaust
    • Exhaust collectors / manifold
  • Fuel System
    • Primary fuel filter
  • General
    • Paint - colors (other than Caterpillar yellow) or high performance paints
    • US aid emblem
  • Generator and Attachments
    • 480 Volts, Generators (LV) 60 Hz, 3 phase, 1800 rpm, FW, PM, 6 leads, pitch = 0.6667 - 1800 frame
    • 480 Volts, Generators (MV) 60 Hz, 3 phase, 1800 rpm, FW, PM, 6 leads, pitch = 0.6667 -- 1800, 3000 frame
    • Space heater kit
    • Thermostat for space heater
    • Differential current transformers (DCT): - 5, 9 and 15 kV class DCTs
  • Instrumentation
    • Pyrometer and thermocouples
    • Harness - ECM interconnect
  • Lube System
    • Lube oil heater
    • Oil pan drain valve
    • Standard sump oil pan
    • Lubricating oil
    • Electric prelube pump
    • Oil filters
  • Crankcase Systems
    • Explosion relief valves
  • Mounting System
    • Rubber anti-vibration mounts
    • Spring-type linear vibration isolators
    • IBC vibration isolators - shipped loose
  • Power Connections
    • Center post busbars (LV) connections
    • Side / Rear monted busbars (LV)
    • Cable entry options (LV)
    • Control packating (LV) - Enclosures
    • Power connection covers
    • Optional package mounted circuit breakers (LV)
    • 4000 Amp, 3 Pole, UL-100% Rated Circuit Breakers
    • 4000 Amp, 3 Pole, IEC-Rated Circuit Breakers
    • 5000 Amp, 3 Pole, UL-100% Rated Circuit Breakers
    • 5000 Amp, 3 Pole, IEC-Rated Circuit Breakers
    • Circuit Breaker Harness
    • MV Power Connection Options: 1800 Frame generator side / rear mounted busbars - Left hand MV nema busbar - Right hand MV nema busbar
    • Cable entry options - 1800 frame (MV)
    • Neutral ground - (MV)
    • Masterpack breaker connections
  • Service Tools - Barring Groups
    • Engine group
    • Group manual
    • Engine air powered
    • Control GP-airpowered group
  • Special Tests / Reports
    • Generator test report
    • PGS test report @ 1.0 power factor
    • PGS test report @ 0.8 power factor
    • Standard genset torsional nibration analysis (TVA) report
    • Custom genset TVA report
    • Fuel consumption test
    • Standard engine test charge
  • Starting/Charging
    • 24 Volt power distribution box
    • 24 Volt electric starting motor
    • Air starting motor
    • Covers - starter locations
    • 24 Volt battery set - dry
    • Heavy duty battery set with rack
    • 35 and 50 Amp battery chargers
    • Jacket water heaters
    • Jacket water heater wiring groups