C4.4 Generator Set Specifications
Fuel System Electronic (adjustable)
Bore 4.13 in
Displacement 268.5 in
Stroke 5 in

Engine Specifications

Fuel System
Electronic (adjustable)
Bore
4.13 in
Displacement
268.5 in
Stroke
5 in
Engine Model
C4.4, In-line 4, 4-cycle diesel
Compression Ratio
18.2:1
Governor Type
Adem™A4
Fuel System
Electronic (adjustable)
Bore
4.13 in
Displacement
268.5 in
Stroke
5 in

Generator Set Specifications

Minimum Rating
36 ekW
Maximum Rating
60 ekW
Voltage
208-600 Volts
Frequency
60 Hz
Speed
1800 RPM
Height - Maximum
53.6 in
Length - Maximum
75.8 in
Width - Maximum
44.1 in

Generator Set Configurations

Emissions/Fuel Strategy
U.S. EPA Certified for Stationary Emergency Use Only (Tier 3 Nonroad Equivalent Emission Standards)
  • Charging System
    • CAT Premium High Output Battery(s) with rack & cables Installed (wet);1000CCA;90amp hr;12V
  • Control System
    • EMCP 4.2
    • Controls include: Run / Auto / Stop Control - Speed Adjust - Engine Cycle Crank - Emergency Stop pushbutton
    • Features include: 12-volt DC operation - Environmental sealed front face - Text alarm/event descriptions
    • Digital indators for: RPM - DC volts - Operating hours, - Oil pressure - Coolant pressure - Volts (L-L & L-N), frequency (Hz) - Amps (per phase & average) - Power Factor (per phase & average) - kW (per phase,average & percent) - kVA (per phase,average & percent) - kVAr (per phase,average & percent) - kW-hr (total) - kVAr-hr (total)
    • Warning / Shutdown with common LED indicators for: -Low Oil pressure - Low coolant temperature alarm (detects jkt water heater failure) - High coolant temperature shutdown
    • Communications: Customer DATA link (Modbus RTU) - RS485 Serial DATA link (terminals only) - 8 programmable digital outputs available - 2 relays pre-programmed - 8 programmable digital inputs available - 2 pre-programmed
  • Circuit Breakers
    • Optional UL/CSA listed mainline breakers
    • Optional Multiple Breakers 100% Rated 3-pole with solid neutral
    • NEMA 1 steel enclosure
    • Electrical stub-up area directly below circuit breaker
  • Cooling System
    • Radiator and cooling fan complete with protective guards
    • Standard ambient temperatues up to 50degC (122degF)
    • 50% coolant antifreeze/corrosion inhibitor
    • Coolant reservoir
  • Generator
    • Insulation system,class H
    • Drip proof generator air intake (NEMA 2,IP23)
    • Electrical design in accordance with BS5000 Part 99,EN61000-6, IEC60034-1,NEMA MG-1.33
    • All electroplated hardware or stainless steel
    • Anticorrosive paint protection
    • High gloss polyurethane paint for durability and scuff resistance
  • Mounting System
    • Heavy-duty fabricated steel base with lifting points
    • Anti-vibration pads to ensure vibration isolaton
    • Complete OSHA guarding
    • Stub-up pipe ready for connection to silencer pipework
    • Flexible fuel lines to base with NPT connections
  • General
    • Warranty per SELF5611
  • Certificates
    • IBC Seismic and Wind Certifications
  • Air Inlet System
    • Cartridge type air filter
  • Charging System
    • NFPA battery charger UL10A 120VAC
  • Circuit Breakers
    • 3-Pole 100% rated
    • Breakers (100% UL rated)
    • Second circuit breaker box
    • Power perminal strips
  • Control Panels
    • NFPA110 bundle includes: FSS low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low Coolant level shut down - WCA1 Low Coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA Battery Charger - A coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
    • Oil temperature guage and sender
    • Audible alarm
    • Ground fault relay
    • Discrete I/O module
    • Remote E-stop button
    • Volt free contacts genset run and common alarm
    • Remote annunciator
    • Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
  • Cooling System
    • Radiator stone guard
    • Radiator transition flange
  • Enclosures
    • Weatherproof enclosure
    • Sound attenuated enclosure, level 1
    • Sound attenuated enclosure, level 2
    • Panel viewing window
    • External emergency stop
  • Heating Elements
    • Coolant heater
    • Jacket water heater
    • Anti-condensation heater
    • Battery heater
    • Lube oil sump heater
    • Wiring for canopy space heater
  • Exhaust System
    • 10, 25 and 35 dBA silencer systems
    • Overhaed silencer mounting kit
  • Fuel System
    • 209 and 394 gallon sub-base fuel tanks
    • 5 gallon fill containment
    • 5 gallon spill containment
    • Emergency vent pipe
    • Tank riser
  • Generators
    • Permanent magnet generator
  • Mounting System
    • Seismic vibration isolators
  • Tests
    • Generator test report
    • PGS test report @ 1.0 power factor
    • PGS test report @ 0.8 power factor
    • 4 Hour factory test