Specification Summary
Exhaust Flange Size (Internal Diameter) 63.5 mm (2.5 in)
Fuel System Electronic (adjustable)
Bore 4.13 in
Displacement 268.5 in

Engine Specifications

Exhaust Flange Size (Internal Diameter)
63.5 mm (2.5 in)
Fuel System
Electronic (adjustable)
Bore
4.13 in
Displacement
268.5 in
Stroke
5 in
Engine Model
C4.4, In-line 4, 4-cycle diesel
Compression Ratio
18.2:1
Governor Type
Adem™A4
Fuel System
Electronic (adjustable)
Bore
4.13 in
Displacement
268.5 in
Stroke
5 in

Generator Set Specifications

Minimum Rating
36 ekW
Maximum Rating
100 ekW
Voltage
220-480 Volts
Frequency
60 Hz
Speed
1800 RPM
Width - Maximum
44.1 in
Height - Maximum
53.6 in
Length - Maximum
75.8 in

Generator Set Configurations

Emissions/Fuel Strategy
Non Regulated, EU Stage II
  • Air Inlet System
    • Air cleaner; light duty with disposable element
  • Cooling System
    • Coolant drain line with valve
    • Fan drive, battery charging alternator drive
    • Caterpillar extended life coolant
    • EMCP 4.1
  • Control Panel
    • Radiator and cooling fan with guards
  • Exhaust System
    • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
  • Fuel System
    • Standard open set fuel tank / base supplied base, formed steel with single wall integral 8-hour fuel tank
  • Generator
  • Governing System
    • Mechanical and electrical governing system - model dependent
  • Lube System
    • Lubricating oil
    • Oil drain line with valve
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provision and drag points
    • Termination points for coolant and lube oil drain lines
  • Starting/Charging System
  • General
    • Engine and alternator pre-paint, Caterpillar yellow
  • Alternator System
    • R frame auxilliary winding
    • LC frame alternator
    • LC frame alternator with coastal insulation protection
    • Permanent magnet
    • 3 phase sensing
    • Quadrature droop kit
    • Anti-condensation heater
  • Circuit Breakers
    • Coolant heater
    • Low coolant temp alarm
  • Cooling System
    • Sound attenuated Level 2 enclosure
    • Sound attenuated Level 1 (galv)
    • Rental pack - CAE rental option only
  • Control Panel Options
  • Enclosures
    • Upgrade to STD set for CE
    • Open set narrow base
    • Compact skidbase for open set
  • European Certifications
  • Fuel System
    • Skidbase for CALG enclosure sets
    • Bunded fuel tank
    • Low fuel level shutdown
    • Low fuel level alarm
    • High fuel level alarm
    • Certification for CIS
    • Electronic governor
  • Global Certifications
  • Mounting Options
    • Battery removal
    • External single point lift - enclosure
    • Industrial silencer
    • Silencer installation kit
    • PGS test report @ 1.0 power factor
  • Special Packing/Inspectons for Shipment
  • General - Accessories / Miscellaneous
    • Stone guards / rad trans flange
    • Packing case - compact set
    • Packing case - canopied set