Starting Small... Building Big! With Alban CAT Construction Equipment...

Learn More
XQ200 Specifications
Rating 200 ekW (250 kVA) Standby
Prime Rating 182 ekW (227.5 kVA)
Frequency 60 Hz
Voltage 208 - 480 V

Generator

Rating
200 ekW (250 kVA) Standby
Prime Rating
182 ekW (227.5 kVA)
Frequency
60 Hz
Voltage
208 - 480 V
Standby Run Time (Full Load)
21.7 Hours
Prime Run Time (Full Load)
24.3 Hours

Engine

Engine
C7.1
Fuel
Requires ULSD

Dimensions

Width
52 in
Height
85 in
Length
161 in
Weight
8916 lb
  • Air Inlet
    • Air cleaner, two stage cyclonic/paper with dust cup and service indicator Series turbocharger and air-to-air aftercooler
  • Charging System
    • 12V - 100 Amp charging alternator
  • Control Panel
    • EMCP 4.2 genset mounted controller
  • Cooling System
    • Package mounted radiator with vertical air discharge provides 43° C ambient capability at standby rating
  • Distribution System
    • NEMA 1 steel enclosure with separate hinged, lockable door.
  • Enclosure
    • Sound attenuating, 12gauge galvanealed sheet metal enclosure limits overall noise to 71 dB(A) @ 7m (23’)
  • Engine
    • EPA Tier 4 Interim technology Cat C7.1 ATAAC heavy duty diesel engine.
  • Exhaust System
    • Cat Clean Emissions Module and integrated silencer with flexible connectors
  • Fuel System
    • 350 gal fuel tank, UL listed, double wall, 24 hr runtime @ 100% prime rating.
  • Generator
    • Three-phase, random wound, 12-lead design, 0.667 pitch
  • Lube System
    • Lubricating oil system including pump, integral oil cooler, lube oil, filter, open crankcase breather with filter
  • Mounting System
    • Generator set soft mounted to the heavy duty, fabricated steel base frame using captive anti-vibration pads between the generator set and base-frame to ensure complete isolation of rotating assemblies.
  • Starting System
    • Single 12V electric starting motor on engine
  • General
    • Factory testing of standard generator set and complete power module
  • ENGINE
    • Battery charger
    • Anti-condensation heater 110-120 VAC
    • Coolant Heater 110-120 VAC
    • Cam lock distribution system
  • GENERATOR
    • Anti-condensation heater 110-120V AC
  • COOLING SYSTEM
    • Coolant heater 110-120V AC
  • MISCELLANEOUS ACCESSORIES
    • Additional operator’s manual pack
    • French or Spanish language labels
    • Canadian Standards Authority certification (CSA)
  • EXTENDED SERVICE COVERAGE
    • Extended service coverage available
  • Trailer
    • Tandem axle trailers with either hydraulic or electric brakes.