C1.5 Marine Generator Set Engine Specifications
Minimum Rating 10 ekW (10 kVA)
Minimum Rating 10 ekW (10 kVA)
Maximum Rating 13 ekW (16.5 kVA)
Maximum Rating 13 ekW (16.5 kVA)

Generator Set Specifications

Minimum Rating
10 ekW (10 kVA)
Minimum Rating
10 ekW (10 kVA)
Maximum Rating
13 ekW (16.5 kVA)
Maximum Rating
13 ekW (16.5 kVA)
Frequency
50 Hz or 60 Hz
Frequency
50 Hz or 60 Hz
Speed
1500 rpm (50Hz) or 1800 rpm (60 Hz)
Speed
1500 rpm (50Hz) or 1800 rpm (60 Hz)

Engine Specifications

Engine Model
C1.5, In-line 3, 4-Stroke-Cycle-Diesel
Engine Model
C1.5, In-line 3, 4-Stroke-Cycle-Diesel
Aspiration
Naturally Aspirated
Aspiration
Naturally Aspirated
Bore
3.31 in
Bore
3.31 in
Stroke
3.5 in
Stroke
3.5 in
Displacement
91.0 in3
Displacement
91 in³
Governor Type
Electrical Isochronous
Governor Type
Electrical Isochronous

Generator Set Configurations

Emissions/Fuel Strategy
60 Hz meets EPA Tier 3*, 50 Hz meets EU 97/68EC Stage II regulations
Emissions/Fuel Strategy
60 Hz meets EPA Tier 3*, 50 Hz meets EU 97/68EC Stage II regulations

Generator Set Dimensions

Weight
319 kg/703 lbs (open), 368 kg/811 lbs (enclosed)
Weight
319 kg/703 lbs (open), 368 kg/811 lbs (enclosed)
Length
37.4 in/962 mm (open), 40 in/1021 mm (enclosed)
Width
21 in/533 mm (open), 24 in/608 mm (enclosed)
Width
21 in/533 mm (open), 24 in/608 mm (enclosed)
Height
27.5 in/699 mm (open), 28 in/710 mm (enclosed)

Generator Specifications

Excitation
AREP
Insulation
Class H
Voltage Regulation
±0.5%
Frame Size
1.5
  • Air Inlet System
    • Air cleaner, single element canister type with rain cap (open generator set only)
  • Control System
    • Electronic isochronous governor
  • Cooling System
    • Belt-driven centrifugal jacket water pump
    • gear-driven seawater pump
    • heat exchanger with copper nickel tubes
    • expansion tank
  • Exhaust System
    • Watercooled exhaust manifold and elbow
  • Fuel System
    • Fuel filter — RH or LH service
    • fuel priming
    • fuel transfer pump
    • flexible fuel lines
  • Generator
    • Single Phase
  • Lube System
    • Lubricating oil
    • oil filter (RH)
    • dipstick (RH)
    • fumes disposal (closed system)
  • Mounting System
    • Anti-vibration mounts, connected to drip tray and steel base sitting on PVC foam sound-absorbent pad
  • Protection System
    • Electronic automatic safety shutdown for low oil pressure, high water temperature, high exhaust (wet exhaust only) temperature, and overspeed
  • Starting System
    • 12 or 24 volt electronic starting motor, 12 volt 55 amp alternator
  • General
    • Single-side service (RH), decals, literature