Starting Small... Building Big! With Alban CAT Construction Equipment...

Learn More
Specification Summary
Minimum Rating 16 ekW (16kVA)
Minimum Rating 16 ekW (16kVA)
Maximum Rating 27 ekW (27 kVA)
Maximum Rating 27 ekW (27 kVA)

Generator Set Specifications

Minimum Rating
16 ekW (16kVA)
Minimum Rating
16 ekW (16kVA)
Maximum Rating
27 ekW (27 kVA)
Maximum Rating
27 ekW (27 kVA)
Frequency
50 Hz or 60 Hz
Frequency
50 Hz or 60 Hz
Speed
1500 rpm (50Hz) or 1800 rpm (60 Hz
Speed
1500 rpm (50Hz) or 1800 rpm (60 Hz

Engine Specifications

Engine Model
C2.2, In-line 4, 4-Stroke-Cycle Diesel
Engine Model
C2.2, In-line 4, 4-Stroke-Cycle Diesel
Aspiration
Naturally Aspirated
Aspiration
Naturally Aspirated
Bore
3.31 in
Bore
3.31 in
Stroke
3.94 in
Stroke
3.94 in
Displacement
135.0 in3
Displacement
135 in³
Governor Type
Electrical Ischronous
Governor Type
Electrical Ischronous
Fuel System
Fuel filter — RH or LH service, fuel priming, fuel transfer pump, flexible fuel lines

Generator Set Configurations

Emissions/Fuel Strategy
EPA Tier 3, IMO NST, EU IW
Emissions/Fuel Strategy
EPA Tier 3, IMO NST, EU IW

Generator Specifications

Excitation
AREP
Pitch
2/3 pitch
Number of Poles
4
Number of Leads
4
Insulation
Class H
Voltage Regulation
±0.5%
Frame Size
2.2
IP Rating
23
Wave Form Deviation - Line to Line
<2%
Voltage Regulator
Steady State

Dimensions & Weights

Length - Open Set
45 in
Length - Enclosed Set
46 in
Width - Open Set
20.5 in
Width - Enclosed Set
24 in
Height - Open Set
32 in
Height - Enclosed Set
31 in
Minimum Approximate Weight
857 lb
Maximum Approximate Weight
1027 lb
  • Air Inlet System
    • Air cleaner, single element canister type with rain cap (open generator set only)
  • Cooling System
    • Belt-driven centrifugal jacket water pump, gear-driven seawater pump, heat exchanger with copper nickel tubes, expansion tank
  • Control System
    • Electronic isochronous governor
  • Exhaust System
    • Watercooled exhaust manifold and elbow
  • Fuel System
    • Fuel filter — RH or LH service, fuel priming, fuel transfer pump, flexible fuel lines
  • Generator
    • Single-phase — brushless, shunt excited, 4-pole, 4-lead reconnectable with class H insulation, automatic voltage regulation ±0.5%, 2/3 pitch, IP23 water protection, solid state voltage regulator with integral voltage adjustment potentiometer, connection poles;
  • Lube System
    • Lubricating oil, oil filter (RH), dipstick (RH), fumes disposal (closed system)
  • Mounting System
    • Anti-vibration mounts, connected to drip tray and steel base sitting on PVC foam sound-absorbent pad
  • Protection System
    • Electronic automatic safety shutdown for low oil pressure, high water temperature, high exhaust (wet exhaust only) temperature, and overspeed
  • Starting System
    • 12 or 24 volt electronic starting motor, 12 volt 55 amp alternator
  • General
    • Single-side service (RH), decals, literature